I opened All Work Items in Microsoft Project from Visual Studio. Made a change in Visual Studio to a Work Item, refreshed Microsoft Project and everything looked alright. Made a change in Microsoft Project and tried to publish and got the TF80070 error. Here is the contents of that log file:
----------------------------------------------------------------------------------------------------------------------------------------------------------------
[Info, PID 5580, TID 4636, 12:57:57.186] Managed ELead Project AddIn loaded [Error, PID 5580, TID 4636, 12:58:04.701] {
[Error, PID 5580, TID 4636, 12:58:04.748] Exception: { Exception Message: An unexpected error occurred with the method. (type COMException)
Exception Stack Trace: at System.RuntimeType.ForwardCallToInvokeMember(String memberName, BindingFlags flags, Object target, Int32[] aWrapperTypes, MessageData& msgData) at Microsoft.Office.Interop.MSProject._MSProject.get_ActiveWindow() at Microsoft.TeamFoundation.OfficeIntegration.Client.Connect.OnConnectionInternal(Object application, ext_ConnectMode connectMode, Object addInInst)
} [Error, PID 5580, TID 4636, 12:58:04.748] } [Error, PID 5580, TID 4636, 12:58:58.139] {
[Error, PID 5580, TID 4636, 12:58:58.139] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.139] } [Error, PID 5580, TID 4636, 12:58:58.623] {
[Error, PID 5580, TID 4636, 12:58:58.623] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.623] } [Error, PID 5580, TID 4636, 12:58:58.655] {
[Error, PID 5580, TID 4636, 12:58:58.655] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.655] } [Error, PID 5580, TID 4636, 12:58:58.733] {
[Error, PID 5580, TID 4636, 12:58:58.733] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.733] } [Error, PID 5580, TID 4636, 12:58:58.795] {
[Error, PID 5580, TID 4636, 12:58:58.795] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.795] } [Error, PID 5580, TID 4636, 12:58:58.842] {
[Error, PID 5580, TID 4636, 12:58:58.842] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.842] } [Error, PID 5580, TID 4636, 12:58:58.889] {
[Error, PID 5580, TID 4636, 12:58:58.889] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.889] } [Error, PID 5580, TID 4636, 12:58:58.920] {
[Error, PID 5580, TID 4636, 12:58:58.920] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.920] } [Error, PID 5580, TID 4636, 12:58:58.967] {
[Error, PID 5580, TID 4636, 12:58:58.967] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.967] } [Error, PID 5580, TID 4636, 12:58:58.983] {
[Error, PID 5580, TID 4636, 12:58:58.998] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:58.998] } [Error, PID 5580, TID 4636, 12:58:59.014] {
[Error, PID 5580, TID 4636, 12:58:59.030] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:59.030] } [Error, PID 5580, TID 4636, 12:58:59.092] {
[Error, PID 5580, TID 4636, 12:58:59.092] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:59.092] } [Error, PID 5580, TID 4636, 12:58:59.123] {
[Error, PID 5580, TID 4636, 12:58:59.123] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:59.123] } [Error, PID 5580, TID 4636, 12:58:59.170] {
[Error, PID 5580, TID 4636, 12:58:59.170] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:59.170] } [Error, PID 5580, TID 4636, 12:58:59.201] {
[Error, PID 5580, TID 4636, 12:58:59.201] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 12:58:59.201] } [Error, PID 5580, TID 4636, 13:00:18.576] {
[Error, PID 5580, TID 4636, 13:00:18.576] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.576] } [Error, PID 5580, TID 4636, 13:00:18.608] {
[Error, PID 5580, TID 4636, 13:00:18.608] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.608] } [Error, PID 5580, TID 4636, 13:00:18.639] {
[Error, PID 5580, TID 4636, 13:00:18.639] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.639] } [Error, PID 5580, TID 4636, 13:00:18.655] {
[Error, PID 5580, TID 4636, 13:00:18.655] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.655] } [Error, PID 5580, TID 4636, 13:00:18.686] {
[Error, PID 5580, TID 4636, 13:00:18.686] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.686] } [Error, PID 5580, TID 4636, 13:00:18.701] {
[Error, PID 5580, TID 4636, 13:00:18.701] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.701] } [Error, PID 5580, TID 4636, 13:00:18.733] {
[Error, PID 5580, TID 4636, 13:00:18.733] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.733] } [Error, PID 5580, TID 4636, 13:00:18.748] {
[Error, PID 5580, TID 4636, 13:00:18.748] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.748] } [Error, PID 5580, TID 4636, 13:00:18.780] {
[Error, PID 5580, TID 4636, 13:00:18.780] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.780] } [Error, PID 5580, TID 4636, 13:00:18.795] {
[Error, PID 5580, TID 4636, 13:00:18.795] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.795] } [Error, PID 5580, TID 4636, 13:00:18.842] {
[Error, PID 5580, TID 4636, 13:00:18.842] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.842] } [Error, PID 5580, TID 4636, 13:00:18.858] {
[Error, PID 5580, TID 4636, 13:00:18.858] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.858] } [Error, PID 5580, TID 4636, 13:00:18.889] {
[Error, PID 5580, TID 4636, 13:00:18.889] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.889] } [Error, PID 5580, TID 4636, 13:00:18.905] {
[Error, PID 5580, TID 4636, 13:00:18.905] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.905] } [Error, PID 5580, TID 4636, 13:00:18.936] {
[Error, PID 5580, TID 4636, 13:00:18.936] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:18.936] } [Error, PID 5580, TID 4636, 13:00:37.748] {
[Error, PID 5580, TID 4636, 13:00:37.826] Exception: { Exception Message: Input string was not in a correct format. (type FormatException)
Exception Stack Trace: at System.Number.StringToNumber(String str, NumberStyles options, NumberBuffer& number, NumberFormatInfo info, Boolean parseDecimal) at System.Number.ParseDouble(String value, NumberStyles options, NumberFormatInfo numfmt) at System.Double.Parse(String s, NumberStyles style, NumberFormatInfo info) at System.Convert.ToDouble(String value, IFormatProvider provider) at System.String.System.IConvertible.ToDouble(IFormatProvider provider) at System.Convert.ChangeType(Object value, Type conversionType, IFormatProvider provider) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.get_Item(String fieldReferenceName) at Microsoft.TeamFoundation.OfficeIntegration.Client.BulkWorkItemUpdater.TryCopyTo(WorkItemBase source, CurrituckWorkItem target)
} [Error, PID 5580, TID 4636, 13:00:37.826] } [Error, PID 5580, TID 4636, 13:00:37.826] {
[Error, PID 5580, TID 4636, 13:00:37.826] Exception: { Exception Message: Input string was not in a correct format. (type FormatException)
Exception Stack Trace: at System.Number.StringToNumber(String str, NumberStyles options, NumberBuffer& number, NumberFormatInfo info, Boolean parseDecimal) at System.Number.ParseDouble(String value, NumberStyles options, NumberFormatInfo numfmt) at System.Double.Parse(String s, NumberStyles style, NumberFormatInfo info) at System.Convert.ToDouble(String value, IFormatProvider provider) at System.String.System.IConvertible.ToDouble(IFormatProvider provider) at System.Convert.ChangeType(Object value, Type conversionType, IFormatProvider provider) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.get_Item(String fieldReferenceName) at Microsoft.TeamFoundation.OfficeIntegration.Client.BulkWorkItemUpdater.TryCopyTo(WorkItemBase source, CurrituckWorkItem target)
} [Error, PID 5580, TID 4636, 13:00:37.826] } [Error, PID 5580, TID 4636, 13:00:45.248] {
[Error, PID 5580, TID 4636, 13:00:45.248] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.248] } [Error, PID 5580, TID 4636, 13:00:45.280] {
[Error, PID 5580, TID 4636, 13:00:45.280] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.280] } [Error, PID 5580, TID 4636, 13:00:45.295] {
[Error, PID 5580, TID 4636, 13:00:45.295] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.295] } [Error, PID 5580, TID 4636, 13:00:45.326] {
[Error, PID 5580, TID 4636, 13:00:45.326] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.326] } [Error, PID 5580, TID 4636, 13:00:45.358] {
[Error, PID 5580, TID 4636, 13:00:45.358] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.358] } [Error, PID 5580, TID 4636, 13:00:45.373] {
[Error, PID 5580, TID 4636, 13:00:45.373] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.373] } [Error, PID 5580, TID 4636, 13:00:45.405] {
[Error, PID 5580, TID 4636, 13:00:45.405] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.405] } [Error, PID 5580, TID 4636, 13:00:45.420] {
[Error, PID 5580, TID 4636, 13:00:45.420] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.420] } [Error, PID 5580, TID 4636, 13:00:45.451] {
[Error, PID 5580, TID 4636, 13:00:45.451] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.451] } [Error, PID 5580, TID 4636, 13:00:45.467] {
[Error, PID 5580, TID 4636, 13:00:45.467] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.467] } [Error, PID 5580, TID 4636, 13:00:45.498] {
[Error, PID 5580, TID 4636, 13:00:45.498] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.498] } [Error, PID 5580, TID 4636, 13:00:45.514] {
[Error, PID 5580, TID 4636, 13:00:45.514] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.514] } [Error, PID 5580, TID 4636, 13:00:45.545] {
[Error, PID 5580, TID 4636, 13:00:45.545] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.545] } [Error, PID 5580, TID 4636, 13:00:45.561] {
[Error, PID 5580, TID 4636, 13:00:45.561] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.561] } [Error, PID 5580, TID 4636, 13:00:45.592] {
[Error, PID 5580, TID 4636, 13:00:45.592] Exception: { Exception Message: This is not a valid Units value. (type COMException)
Exception Stack Trace: at Microsoft.Office.Interop.MSProject.Task.SetField(PjField FieldID, String Value) at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectWorkItem.set_Item(String fieldReferenceName, Object value)
} [Error, PID 5580, TID 4636, 13:00:45.592] } [Error, PID 5580, TID 4636, 13:00:45.655] {
[Error, PID 5580, TID 4636, 13:00:45.655] Exception: { Exception Message: Stack empty. (type InvalidOperationException)
Exception Stack Trace: at System.ThrowHelper.ThrowInvalidOperationException(ExceptionResource resource) at System.Collections.Generic.Stack`1.Pop() at Microsoft.TeamFoundation.OfficeIntegration.Client.WorkItemDictionaryBase.UnFilter() at Microsoft.TeamFoundation.OfficeIntegration.Client.ChopSuiHelper.Sync1(ChopPacket chopPacket, Int32& publishedItemsCount) at Microsoft.TeamFoundation.OfficeIntegration.Client.ChopSuiHelper.Sync(IWin32Window parent, OfficeWorkItemDictionaryBase localDictionary, ProjectContext projectContext, Boolean publishToDB, WorkItemRefreshOption refreshOptions, CultureInfo uiCultureInfo) at Microsoft.TeamFoundation.OfficeIntegration.Client.ELeadProjectPlan.Sync(Boolean publishToDB) at Microsoft.TeamFoundation.OfficeIntegration.Client.ELeadProjectPlan.Synchronize() at Microsoft.TeamFoundation.OfficeIntegration.Client.ProjectCommands.SynchronizeCommand_Click(CommandBarButton cmdBarbutton, Boolean& cancel)
} [Error, PID 5580, TID 4636, 13:00:45.655] }
|